R720E is a wireless communication device that detects temperature, humility and TVOC. TVOC refers to all organic gaseous substances in a space, and generally refers to the indoor volatile organic substances. TVOC is also the much serious one of the three types of pollution affecting indoor air quality. R720E can detect the concentration value of TVOC.
R720F series is a wireless communication device that can detect the existence of hand sanitizer / water leakage. This device is connected with two electrode rods which
can be used to detect the state of the insufficient amount of hand sanitizer in the hand sanitizer box or whether there is the water leakage in the detection area.
The shape and orientation of electrode rod can be selected according to the needs
(R720FLO,R720FLD,R720FU). The electrode rod can be trimmed to the required
length by self according to the demand.
The function of water leakage detection can choose R720FW.
R72601 is a wireless communication device that detects the carbon monoxide content in ambient air. The
body and the sensor are connected through the RS485 interface, and the detected data is transmitted to data
center through the wireless network for display. It adopts the wireless communication method conforming to
the LoRaTM protocol standard.
R72608 is a device used for pH and water temperature detection of the water environment. It can detect and
send the data of pH and temperature by the wireless communication method which adopts SX1276 wireless
communication module.
R72610 is a wireless communication device for turbidity detection. R72610 can detect the turbidity of the solution. The host body and the turbidity sensor communicate through RS485. The turbidity sensor can also detect the water temperature and transmit the detected data to other devices through the wireless network for display.
The R72611 is a wireless communication device that detects the depth of a liquid. The R72611 detects the depth of the liquid in the container. The main part and the sensor are connected via the RS485 interface, and the detected data is transmitted to other devices through the wireless network. The wireless communication method conforms to the LoRaTM protocol standard.
Note: Different types of liquids have different requirements for the sensor, so it is necessary to select the sensor according to the type of liquid.
The R72615 is equipped with a temperature and humidity sensor that detects and transmits ambient
temperature and humidity data. It is a wireless communication method that uses the SX1276 wireless
communication module. The R72615 has a CO2 sensor that detects the concentration of CO2 in the air.
R72615A has a temperature and humidity sensor that detects and transmits ambient temperature and humidity data. It applies wireless communication method that uses the SX1276 wireless communication module. The R72615A has a CO2 sensor that detects the concentration of CO2 in the air.
The R72616 is equipped with a temperature and humidity sensor that detects and transmits ambient temperature and humidity data. It is a wireless communication method that uses the SX1276 wireless communication module. The R72616 has a PM2.5 sensor that detects the concentration of PM2.5 in the air.
R72616A with temperature and humidity sensor can detect and send the temperature and humidity data of the environment. The device is in line with the LoRa protocol standard. R72616A with PM2.5 dust sensor can be used to obtain the concentration of suspended particulates in air per unit volume.
NETVOX Wireless Sensor R72623 is capable to measure PM2.5 / noise / temperature / humidity at outdoor environment.
• R72623 can be used in construction site / agricultural environment / airport surroundings / business environment data collection. Suitable as a data logger.
R72624 has the built-in noise detector and the built-in temperature and humidity sensor that can
detect the value of noise, temperature and humidity and transmit the detected data to other device
via the wireless network for display.
R72630 is equipped with wind speed sensor, wind direction sensor, and temperature and humidity
sensor. It can detect and send the data of the wind speed, wind direction, temperature and humidity of the
environment. It adopts a wireless communication method and conforms to the LoRa protocol standard. It
can detect the four elements of the air.
R72632A can detect and send soil nitrogen (N), phosphorus (P) and potassium (K) data. It is a
wireless communication mode, adopts SX1276 wireless communication module.
R72632A01 can detect and send soil nitrogen (N), phosphorus (P) and potassium (K) data. It is a
wireless communication mode, adopts SX1276 wireless communication module.
This equipment is used to detect temperature of the object and medium which thermocouple is contacted. It can be connected to two thermocouples for testing.