Actuators

Showing 17–32 of 68 results

  • MDT LED Controller 4-channel, 4/8 A, RGBW, 4SU MDRC

    0 out of 5
    د.إ1,061.28

    LED Controller 4-channel, 4/8 A, RGBW, 4SU MDRC. Suitable for 12/24 V CV LED, 4 separate channels or RGBW, TW. Comprehensive application. Absolute and relative dimming for HSV colour space and RGB. Tunable White colour temperature control. Selectable dimming curve and PWM frequency up to 1000 Hz. Global and individual dimming speeds. Individual and predefined sequences (e.g. TV Simulator). Repetition of sequences for automatic colour control. Suitable for 12/24 V CV LED (Common Anode). Selectable load distribution: 4 channels each 4 A or 1 channel 7 A and 3 channels each 3 A. Parallel operation of 2 channels with 8 A. Operating modes: 4 x White, RGB, RGBW, Tunable White. Automatic colour temperature control Dim2Warm. Dynamic daylight control HCL.(Human Centric Lighting). Automatic time dependent dimming. Day/Night function. Overcurrent and overtemperature supervision. Intelligent 16 A C-Load relay output to control external.LED power supply. 3 year warranty.

  • MDT LED Controller CC/CV 60 W / 230 V 2-Channel

    0 out of 5
    د.إ1,142.35

    LED Controller CC/CV 60 W / 230 V 2-Channel. Version with integrated power supply in compact design. Constant current LED controller with max. output current of 1.400 mA. Optimised Hybrid dimming for a better Light quality. Comprehensive Application, absolute und relative Dimming. Dim range von 0,2 % to 100 %. Perfect dim behaviour over the entire dimming range. Maximum output power 60 W over both channels. Max output current 1.400 mA. Constant current selectable via DIP switch. Tunable White colour temperature control. Selectable Dim curve, individual sequences. Operation mode: 2x white, Tunable White. Automatic colour temperature control Dim2Warm. Dynamic daylight control HCL. Automatic time dependent dimming. Day / Night Function. Overcurrent and temperature monitoring. Secondary connection up to 6 m. Integrated power supply in compact design. Dimensions (W x H X D): 129 mm x 54 mm x 25 mm. 3 Year warranty.

  • MDT Object Controller 55, White glossy finish

    0 out of 5
    د.إ626.45

    Object Controller 55, White glossy finish. With temperature/humidy sensor and 4 inputs. Flush mounted. Integrated BCU. Fits 55 mm systems/ranges: – GIRA Standard 55, E2,E22, Event, Esprit. – BERKER S1, B3, B7. – JUNG A500, Aplus, Acreation, AS500. – MERTEN 1M, M-Smart, M-Plan, M-Pure. Room temperature controller for indoor rooms Range -10 to +50 °C. Selectable temperature controller (PI, Two-position, PWM). 1 Bit +/-, 1 Byte oder 2 Byte absolute object for setpoint adjustment. Setpoint values are stored at bus voltage failure. Limit values min/max, frost protection alarm, min/max memory. Operation mode can be set via Bit/Byte objects. Temperature and humidy sensor with dew point calculation. Message when leaving the comfort zone. 4 binary inputs to connect potential free contacs (push-buttons or window/auxiliary contacts). Ventilation control by hand or automatic operation. 14 Byte object for plain text diagnostic. Installation in a installation box with included support ring. Recommended installation height: 1,60 m. Integrated bus coupling unit. 3 year warranty.

  • MDT Shutter Actuator 1-fold, 6 A, for 230 V AC shutter motors, with 4 binary inputs

    0 out of 5
    د.إ589.60

    Shutter Actuator 1-fold, 6 A, for 230 V AC shutter motors, with 4 binary inputs. For 230 V AC shutter motors up to 300 W. With 4 binary inputs and sun position calculation. Shutter/blind functions: Practical ventilation function (window open/tilt). Automatic sun shading/slat adjustment with sun position calculation. Travel-, pause-at-change-of-direction and step time adjustable. Separate travel time for up and down adjustable. Tip operation for accurate positioning. Extended 1 Bit automatic positions and logical functions. 1 Byte absolute positioning for shutter and blinds. Alarm, central- and block functions. Priority/forced operation with automatic release time. Adjustable behavior in case of bus voltage return.Functions Binary Inputs: To connect push-buttons or window/auxiliary contacts. Integrated evaluation of the windows contacts. Adjustable transmission behavior of the up/down objects. (To the internal contacs or actuators on the KNX bus). Operation of blinds and shutters, 1 and 2 button operation. Binary Inputs usable as Universal Interface. Dimensions (W x H x D): 41 mm x 41 mm x 22 mm. 3 year warranty.

  • MDT Shutter Actuator 1-fold, flush mounted, 6 A, 230 V AC

    0 out of 5
    د.إ490.11

    Shutter Actuator 1-fold, flush mounted, 6 A, 230 V AC. Shutter Actuator to feed 230 V AC shutter motors up to 300 W. Comprehensive application. Operation mode blind/shutter. Practical ventilation function (window open/tilt). Travel-, pause-at-change-of-direction and step time adjustable. Separate travel time for up and down adjustable. Tip operation for accurate positioning. Extended 1 Bit automatic positions and logical functions. 1 Byte absolute positioning for shutter and blinds. Alarm, central- and block functions. Behavior after alarms and block separately adjustable. Priority/forced operation with automatic release time. Adjustable behavior in case of bus voltage return. Dimensions (W x H x D): 41 mm x 41 mm x 22 mm. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Shutter Actuator 2-fold, 2SU MDRC, 8 A, 230 V AC

    0 out of 5
    د.إ781.22

    Shutter Actuator 2-fold, 2SU MDRC, 8 A, 230 V AC. For 230 V AC shutter motors up to 300 W. With sun position calculation. Comprehensive application. Lockable manual operation and LED indicator for each channel. Operation mode blind/shutter. Practical ventilation function (window open/tilt). Automatic sun shading/slat adjustment with sun position calculation. Travel-, pause-at-change-of-direction and step time adjustable. Separate travel time for up and down adjustable. Tip operation for accurate positioning. Extended 1 Bit automatic positions and logical functions. 1 Byte absolute positioning for shutter and blinds. Alarm, central- and block functions. Behavior after alarms and locking separately configurably. Priority/forced operation with automatic release time. Adjustable behavior in case of bus voltage failure/return. Two contacts share one L-connection. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Shutter Actuator 4-fold with travel time measurement

    0 out of 5
    د.إ1,319.23

    Shutter Actuator 4-fold with travel time measurement. 4SU MDRC, 8 A, 230 V AC, to feed 230 V AC motors up to 300 W. With sun position calculation. Comprehensive application. Travel times are automatically measured and stored. Lockable manual operation and LED indicator for each channel. Operation mode blind/shutter. Practical ventilation function (window open/tilt). Automatic sun shading/slat adjustment with sun position calculation. Travel-, pause-at-change-of-direction and step time adjustable. Separate travel time for up and down adjustable. Tip operation for accurate positioning. Extended 1 Bit automatic positions and logical functions. 1 Byte absolute positioning for shutter and blinds. Alarm, central- and block functions. Behavior after alarms and locking separately configurably. Priority/forced operation with automatic release time. Adjustable behavior in case of bus voltage failure/return. Two contacts share one L-connection. 3 year warranty.

  • MDT Shutter Actuator 4-fold, 4SU MDRC, 8 A, 230 V AC

    0 out of 5
    د.إ1,190.26

    Shutter Actuator 4-fold, 4SU MDRC, 8 A, 230 V AC. For 230 V AC shutter motors up to 300 W. With sun position calculation. Comprehensive application. Lockable manual operation and LED indicator for each channel. Operation mode blind/shutter. Practical ventilation function (window open/tilt). Automatic sun shading/slat adjustment with sun position calculation. Travel-, pause-at-change-of-direction and step time adjustable. Separate travel time for up and down adjustable. Tip operation for accurate positioning. Extended 1 Bit automatic positions and logical functions. 1 Byte absolute positioning for shutter and blinds. Alarm, central- and block functions. Behavior after alarms and locking separately configurably. Priority/forced operation with automatic release time. Adjustable behavior in case of bus voltage failure/return. Two contacts share one L-connection. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Shutter Actuator 4-fold, 4SU MDRC, 8 A, 24 V DC

    0 out of 5
    د.إ1,205

    Shutter Actuator 4-fold, 4SU MDRC, 8 A, 24 V DC. For 24 V DC shutter motors up to 180 W. With sun position calculation. Lockable manual operation and LED indicator for each channel. Operation mode blind/shutter. Practical ventilation function (window open/tilt). Automatic sun shading/slat adjustment with sun position calculation. Travel-, pause-at-change-of-direction and step time adjustable. Separate travel time for up and down adjustable. Tip operation for accurate positioning. Extended 1 Bit automatic positions and logical functions. 1 Byte absolute positioning for shutter and blinds. Alarm, central- and block functions. Behavior after alarms and locking separately configurably. Priority/forced operation with automatic release time. To feed 24 V DC motors with 2 connections. Integrated commutator circuit. Adjustable behavior in case of bus voltage failure/return. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Shutter Actuator 8-fold with travel time measurement

    0 out of 5
    د.إ2,056.23

    Shutter Actuator 8-fold with travel time measurement. 8SU MDRC, 8 A, 230 V AC, to feed 230 V AC motors up to 300 W. With sun position calculation. Comprehensive application. Travel times are automatically measured and stored. Lockable manual operation and LED indicator for each channel. Operation mode blind/shutter. Practical ventilation function (window open/tilt). Automatic sun shading/slat adjustment with sun position calculation. Travel-, pause-at-change-of-direction and step time adjustable. Separate travel time for up and down adjustable. Tip operation for accurate positioning. Extended 1 Bit automatic positions and logical functions. 1 Byte absolute positioning for shutter and blinds. Alarm, central- and block functions. Behavior after alarms and locking separately configurably. Priority/forced operation with automatic release time. Adjustable behavior in case of bus voltage failure/return. Two contacts share one L-connection. 3 year warranty.

  • MDT Shutter Actuator 8-fold, 8SU MDRC, 8 A, 230 V AC

    0 out of 5
    د.إ1,794.60

    Shutter Actuator 8-fold, 8SU MDRC, 8 A, 230 V AC. For 230 V AC shutter motors up to 300 W. With sun position calculation. Comprehensive application. Lockable manual operation and LED indicator for each channel. Operation mode blind/shutter. Practical ventilation function (window open/tilt). Automatic sun shading/slat adjustment with sun position calculation. Travel-, pause-at-change-of-direction and step time adjustable. Separate travel time for up and down adjustable. Tip operation for accurate positioning. Extended 1 Bit automatic positions and logical functions. 1 Byte absolute positioning for shutter and blinds. Alarm, central- and block functions. Behavior after alarms and locking separately configurably. Priority/forced operation with automatic release time. Adjustable behavior in case of bus voltage failure/return. Two contacts share one L-connection. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Shutter Actuator 8-fold, 8SU MDRC, 8 A, 24 V DC

    0 out of 5
    د.إ1,809.34

    Shutter Actuator 8-fold, 8SU MDRC, 8 A, 24 V DC. For 24 V DC shutter motors up to 180 W. With sun position calculation. Lockable manual operation and LED indicator for each channel. Operation mode blind/shutter. Practical ventilation function (window open/tilt). Automatic sun shading/slat adjustment with sun position calculation. Travel-, pause-at-change-of-direction and step time adjustable. Separate travel time for up and down adjustable. Tip operation for accurate positioning. Extended 1 Bit automatic positions and logical functions. 1 Byte absolute positioning for shutter and blinds. Alarm, central- and block functions. Behavior after alarms and locking separately configurably. Priority/forced operation with automatic release time. To feed 24 V DC motors with 2 connections. Integrated commutator circuit. Adjustable behavior in case of bus voltage failure/return. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 1-fold, flush mounted, 16 A, 230 V AC, C-load, Standard, 140 μF

    0 out of 5
    د.إ490.11

    Switch Actuator 1-fold, flush mounted, 16 A, 230 V AC, C-load, Standard, 140 µF.
    For installation in switch box, version with bistable relay. Current max. 16 A, capacitive load max. 140 μF.
    Comprehensive application. NO and NC contact operation. Extended status functions (inverted, cyclic, at block).
    Time functions (switch-on/switch-off delay). Extensive staircase light and impulse functions.
    Extended logical and scene functions. Treshold switch (Byte/2 Byte/2 Byte float). Hour meter for switching.
    Priority/forced operation with automatic release time. Quick application download (long frame support for ETS 5).
    Flush mounted in an installation box. Dimensions (W x H x D): 41 mm x 41 mm x 22 mm. 3 year warranty

  • MDT Switch Actuator 1-fold, flush mounted, 16 A, 70 μF, 10 ECG, 230 V AC, Compact

    0 out of 5
    د.إ442.20

    Switch Actuator 1-fold, flush mounted, 16 A, 70 µF, 10 ECG, 230 V AC, Compact. Flush mounted Switch Actuator with bistable relays. Current max. 16 A with ohmic load, 70 μF / 10 ECG. Function extension. NO and NC contact operation. Time functions (switch-on/switch-off delay). Extensive staircase light and impulse functions. Status response (active/passive) for each channel. Logical linking of binary data. Extendend scene functions for each channel. Central switching functions and block functions. Adjustable behaviour in case of bus voltage failure or return. Flush mounted in an installation box. Dimensions (W x H x D): 41 mm x 41 mm x 22 mm. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 12-fold, 12SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF, current measurement

    0 out of 5
    د.إ2,170.47

    Switch Actuator 12-fold, 12SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF, current measurement. Standard version with bistable relays.
    Comprehensive application. Integrated True RMS current measurement (current, kWh). Current measurement range 10 mA to 16 A. Integrated energy consumption meter function (Wh/kWh). Fast reaction <1s at Master/Slave operation. Push Button for manual operation and LED indicator for each channel. Time functions (switch-on/switch-off delay, staircase light function). Threshold switch function and Consumption threshold value. Logical linking of binary data, 8 scenes per channel. Operating hours meter. Extended status functions (inverted, cyclic, when locked). Priority / forced operation with automatic release time. Adjustable behaviour on bus voltage failure / -return. All L-connections separated, 4 mm² / 2 x 2,5 mm² connection terminals. 3 year warranty.

  • MDT Switch Actuator 12-fold, 12SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF

    0 out of 5
    د.إ2,026.75

    Switch Actuator 12-fold, 12SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF. Switch Actuator with bistable relays, for heavy C-loads. Current max. 16/20 A, capacitive load max. 200 μF. Comprehensive function extension. Mechanical manual operation for direct actuation of the relay contact, status visible. NO and NC contact operation. Time functions (switch-on/switch-off delay). Extensive staircase light and impulse functions. Extended logical and scene functions for each channel. Extended status functions (inverted, cyclic, at block). Treshold switch (Byte/2 Byte/2 Byte float). Hour meter for switching. Priority/forced operation with automatic release time. 4 mm² / 2×2,5 mm² screw terminals. Separate supply phases. Power supply via KNX bus. Quick application download (long frame support for ETS5). 3 year warranty.

End of content

End of content