Actuators

Showing 49–64 of 68 results

  • MDT Switch Actuator 4-fold, 2SU MDRC, 16 A, 230 V AC, compact, 70 µF, 10 ECG, Fan coil

    0 out of 5
    د.إ910.20

    Switch Actuator 4-fold, 2SU MDRC, 16 A, 230 V AC, compact, 70 µF, 10 ECG, Fan coil. Compact Switch Actuator with bistable relays. Current max. 16 A with ohmic load, 70 μF / 10 ECG. Fan coil mode: Control of 3-/4-speed fans/ventilator convectors. Additional switching output at 3-speed operation. Outputs are interlocked. Direct operation by three 1 Bit objects or a single 1 Bit object (+/-). Automatic operation by 1 Byte control value (0-100 %). Suitable for 2-pipe systems and 4-pipe systems. Output objects to control valves for heating/cooling. Day/Night function to limit fan speed at night. Emergency operation if variable fails.Switch Actuator mode: NO and NC contact operation. Time functions (switch-on/switch-off delay). Staircase light function with adjustable warning time. Status response (active/passive) for each channel. Logical linking of binary data, 8 scenes per channel. Central switching functions and block functions. Adjustable behaviour in case of bus voltage failure or return. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 4-fold, 4SU MDRC, 10 A, 230 V AC, C-load, standard, 140 μF

    0 out of 5
    د.إ998.64

    Switch Actuator 4-fold, 4SU MDRC, 10 A, 230 V AC, C-load, standard, 140 μF. Switch Actuator with bistable relays. Current max. 10 A, capacitive load max. 140 μF. Space saving design. Comprehensive function extension. Lockable manual operation and LED indicator for each channel. NO and NC contact operation. Status response at manually operation. Time functions (switch-on/-off delay, staircase light functions). Extended logical and scene functions for each channel. Extended status functions (inverted, cyclic, at block). Treshold switch (Byte/2 Byte/2 Byte float). Hour meter for switching. Priority/forced operation with automatic release time. Separate power supply terminals for each channel. Power supply via KNX bus. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 4-fold, 4SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF

    0 out of 5
    د.إ1,076.02

    Switch Actuator 4-fold, 4SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF. Switch Actuator with bistable relays. Current max. 16 A, capacitive load max. 140 μF. Space saving design. Comprehensive function extension. Lockable manual operation and LED indicator for each channel. NO and NC contact operation. Status response at manually operation. Time functions (switch-on/-off delay, staircase light functions). Extended logical and scene functions for each channel. Extended status functions (inverted, cyclic, at block). Treshold switch (Byte/2 Byte/2 Byte float). Hour meter for switching. Priority/forced operation with automatic release time. Separate power supply terminals for each channel. Power supply via KNX bus. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 4-fold, 4SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF, current measurement

    0 out of 5
    د.إ1,263.96

    Switch Actuator 4-fold, 4SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF, current measurement. Standard version with bistable relays.
    Comprehensive application. Integrated True RMS current measurement (current, kWh). Current measurement range 10 mA to 16 A. Integrated energy consumption meter function (Wh/kWh). Fast reaction <1s at Master/Slave operation. Push Button for manual operation and LED indicator for each channel. Time functions (switch-on/switch-off delay, staircase light function). Threshold switch function and Consumption threshold value. Logical linking of binary data, 8 scenes per channel. Operating hours meter. Extended status functions (inverted, cyclic, when locked). Priority / forced operation with automatic release time. Adjustable behaviour on bus voltage failure / -return. All L-connections separated, 4 mm² / 2 x 2,5 mm² connection terminals. 3 year warranty.

  • MDT Switch Actuator 4-fold, 4SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF

    0 out of 5
    د.إ1,219.74

    Switch Actuator 4-fold, 4SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF. Switch Actuator with bistable relays, for heavy C-loads. Current max. 16/20 A, capacitive load max. 200 μF. Comprehensive function extension. Mechanical manual operation for direct actuation of the relay contact, status visible. NO and NC contact operation. Time functions (switch-on/switch-off delay). Extensive staircase light and impulse functions. Extended logical and scene functions for each channel. Extended status functions (inverted, cyclic, at block). Treshold switch (Byte/2 Byte/2 Byte float). Hour meter for switching. Priority/forced operation with automatic release time. 4 mm² / 2×2,5 mm² screw terminals. Separate supply phases. Power supply via KNX bus. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 4-fold, 4SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF, current measurement

    0 out of 5
    د.إ1,367.14

    Switch Actuator 4-fold, 4SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF, current measurement. Industrial version with bistable relays.
    Comprehensive application. Integrated True RMS current measurement (current, kWh). Current measurement range 10 mA to 20 A. Integrated energy consumption meter function (Wh/kWh). Fast reaction <1s at Master/Slave operation. Push Button for manual operation and LED indicator for each channel. Time functions (switch-on/switch-off delay, staircase light function). Threshold switch function and Consumption threshold value. Logical linking of binary data, 8 scenes per channel. Operating hours meter. Extended status functions (inverted, cyclic, when locked). Priority / forced operation with automatic release time. Adjustable behaviour on bus voltage failure / -return. All L-connections separated, 4 mm² / 2 x 2,5 mm² connection terminals. 3 year warranty.

  • MDT Switch Actuator 6-fold, 8SU, MDRC, 16/20 A, 230 V AC, C-load, 200μF, power measurement

    0 out of 5
    د.إ1,879.35

    Switch Actuator 6-fold, 8SU, MDRC, 16/20 A, 230 V AC, C-load, 200 µF, power measurement. Industrial version with bistable relays.
    Comprehensive application. Integrated True RMS current measurement and voltage measurement. True active power meter (Wh / kWh). Current measurement range 10 mA to 20 A. Active power-, reactive power-, current- and voltage values. Push Button for manual operation and LED indicator for each channel. Time functions (switch-on/switch-off delay, staircase light function). Threshold switch function and Consumption threshold value. Priority / forced operation with automatic release time. Logical linking of binary data, 8 scenes per channel. Operating hours meter. Extended status functions (inverted, cyclic, when locked). Adjustable behaviour on bus voltage failure / -return. All L-connections separated, 4 mm² / 2 x 2,5 mm² connection terminals. 3 year warranty.

  • MDT Switch Actuator 8-fold, 4SU MDRC, 16 A, 230 V AC, compact, 70 µF, 10 ECG

    0 out of 5
    د.إ1,271.33

    Switch Actuator 8-fold, 4SU MDRC, 16 A, 230 V AC, compact, 70 µF, 10 ECG. Compact Switch Actuator with bistable relays. Current max. 16 A with ohmic load, 70 μF / 10 ECG. Function extension. Lockable manual operation and LED indicator for each channel. NO and NC contact operation. Status response at manually operation. Time functions (switch-on/switch-off delay). Extensive staircase light and impulse functions. Status response (active/passive) for each channel. Logical linking of binary data. Extendend scene functions for each channel. Central switching functions and block functions. Adjustable behavior in case of bus voltage failure/return. Separate L-connections. Power supply via KNX bus. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 8-fold, 6SU MDRC, 10 A, 230 V AC, C-load, standard, 140 μF

    0 out of 5
    د.إ1,400.30

    Switch Actuator 8-fold, 6SU MDRC, 10 A, 230 V AC, C-load, standard, 140 μF. Switch Actuator with bistable relays. Current max. 10 A, capacitive load max. 140 μF. Space saving design. Comprehensive function extension. Lockable manual operation and LED indicator for each channel. NO and NC contact operation. Status response at manually operation. Time functions (switch-on/-off delay, staircase light functions). Extended logical and scene functions for each channel. Extended status functions (inverted, cyclic, at block). Treshold switch (Byte/2 Byte/2 Byte float). Hour meter for switching. Priority/forced operation with automatic release time. Separate power supply terminals for each channel. Power supply via KNX bus. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 8-fold, 6SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF

    0 out of 5
    د.إ1,488.74

    Switch Actuator 8-fold, 6SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF. Switch Actuator with bistable relays. Current max. 16 A, capacitive load max. 140 μF. Space saving design. Comprehensive function extension. Lockable manual operation and LED indicator for each channel. NO and NC contact operation. Status response at manually operation. Time functions (switch-on/-off delay, staircase light functions). Extended logical and scene functions for each channel. Extended status functions (inverted, cyclic, at block). Treshold switch (Byte/2 Byte/2 Byte float). Hour meter for switching. Priority/forced operation with automatic release time. Separate power supply terminals for each channel. Power supply via KNX bus. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 8-fold, 8SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF, current measurement

    0 out of 5
    د.إ1,743.01

    Switch Actuator 8-fold, 8SU MDRC, 16 A, 230 V AC, C-load, standard, 140 μF, current measurement. Standard version with bistable relays.
    Comprehensive application. Integrated True RMS current measurement (current, kWh). Current measurement range 10 mA to 16 A. Integrated energy consumption meter function (Wh/kWh). Fast reaction <1s at Master/Slave operation. Push Button for manual operation and LED indicator for each channel. Time functions (switch-on/switch-off delay, staircase light function). Threshold switch function and Consumption threshold value. Logical linking of binary data, 8 scenes per channel. Operating hours meter. Extended status functions (inverted, cyclic, when locked). Priority / forced operation with automatic release time. Adjustable behaviour on bus voltage failure / -return. All L-connections separated, 4 mm² / 2 x 2,5 mm² connection terminals. 3 year warranty.

  • MDT Switch Actuator 8-fold, 8SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF

    0 out of 5
    د.إ1,661.94

    Switch Actuator 8-fold, 8SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF. Switch Actuator with bistable relays, for heavy C-loads. Current max. 16/20 A, capacitive load max. 200 μF. Comprehensive function extension. Mechanical manual operation for direct actuation of the relay contact, status visible. NO and NC contact operation. Time functions (switch-on/switch-off delay). Extensive staircase light and impulse functions. Extended logical and scene functions for each channel. Extended status functions (inverted, cyclic, at block). Treshold switch (Byte/2 Byte/2 Byte float). Hour meter for switching. Priority/forced operation with automatic release time. 4 mm² / 2×2,5 mm² screw terminals. Separate supply phases. Power supply via KNX bus. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Switch Actuator 8-fold, 8SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF, current measurement

    0 out of 5
    د.إ1,853.56

    Switch Actuator 8-fold, 8SU MDRC, 16/20 A, 230 V AC, C-load, industrie, 200 μF, current measurement. Industrial version with bistable relays.
    Comprehensive application. Integrated True RMS current measurement (current, kWh). Current measurement range 10 mA to 20 A. Integrated energy consumption meter function (Wh/kWh). Fast reaction <1s at Master/Slave operation. Push Button for manual operation and LED indicator for each channel. Time functions (switch-on/switch-off delay, staircase light function). Threshold switch function and Consumption threshold value. Logical linking of binary data, 8 scenes per channel. Operating hours meter. Extended status functions (inverted, cyclic, when locked). Priority / forced operation with automatic release time. Adjustable behaviour on bus voltage failure / -return. All L-connections separated, 4 mm² / 2 x 2,5 mm² connection terminals. 3 year warranty.

  • MDT Universal Actuator 16-fold, 8SU MDRC, 16 A, 230 V AC, 100 μF, 15 ECG

    0 out of 5
    د.إ2,052.55

    Universal Actuator 16-fold, 8SU MDRC, 16 A, 230 V AC, 100 μF, 15 ECG. Compact design with bistable relays. Current max. 16 A with ohmic load, 100 μF / 15 ECG. With sun position calculation / shading. Comprehensive function extension. Can be used as Switch Actuator (max. 16-fold) or Shutter Actuator (max. 8-fold). Mixed applications of Switch- and Shutter Actuator possible. Heating control with PWM 0-100 %. Push Button and LED indicator for each channel. Practical ventilation function (window open/tilted). Automatic shading / slat tracking with sun position calculation. Time functions (switch-on/-off delay, staircase light function). Status response (active/passive) for each channel. Logical linking of binary data, 8 scenes per channel. Central switching functions and block functions. Operation mode blind/shutter adjustable. Running, pause and step time freely adjustable. Adjustable behavior in case of bus voltage failure/return. 4 mm² / 2×2,5 mm² connection terminals. Separate L-connections. 3 year warranty.

  • MDT Universal Actuator 2-fold, flush mounted, 10 A, 230 V AC, 14 μF, 2ECG

    0 out of 5
    د.إ530.64

    Universal Actuator 2-fold, flush mounted, 10 A, 230 V AC, 14 µF, 2 ECG. Flush-mounted version with monostable relay. Current max. 10 A with ohmic load, 14 μF / 2 ECG. With sun position calculation / shading. Can be used as switch actuator 2-fold or as blind actuator 1-fold. Heating control with PWM 0-100 %. Practical ventilation function (window open/tilted). Automatic shading / slat tracking with sun position calculation. Time functions (switch-on/-off delay, staircase light function). Status response (active/passive) for each channel. Logical linking of binary data, 8 scenes per channel. Central switching functions and block functions. Operation mode blind/shutter adjustable. Running, pause and step time freely adjustable. Adjustable behavior in case of bus voltage failure/return. Dimensions (W x H x D): 41 mm x 41 mm x 22 mm. 3 year warranty.

  • MDT Universal Actuator 2-fold, flush mounted, 10 A, 230 V AC, 14 μF, 2ECG with 4 binary inputs

    0 out of 5
    د.إ619.08

    Universal Actuator 2-fold, flush mounted, 10 A, 230 V AC, 14 µF, 2ECG with 4 binary inputs. Flush-mounted version with monostable relay. Current max. 10 A with ohmic load, 14 μF / 2 ECG. With sun position calculation / shading. Can be used as switch actuator 2-fold or as blind actuator 1-fold. Heating control with PWM 0-100 %. Practical ventilation function (window open/tilted). Automatic shading / slat tracking with sun position calculation. 4 binary inputs for connecting pushbuttons, switches and window contacts. Time functions (switch-on/-off delay, staircase light function). Status response (active/passive) for each channel. Logical linking of binary data, 8 scenes per channel. Central switching functions and block functions. Operation mode blind/shutter adjustable. Running, pause and step time freely adjustable. Adjustable behavior in case of bus voltage failure/return. Dimensions (W x H x D): 41 mm x 41 mm x 22 mm. 3 year warranty.

End of content

End of content