Room Temperature Extension Unit Smart 55, White glossy finish. With colour display, temperature and humidity sensor. Flush mounted. Integrated BCU. Fits 55 mm systems/ranges: – GIRA Standard 55, E2,E22, Event, Esprit. – BERKER S1, B3, B7. – JUNG A500, Aplus, Acreation, AS500. – MERTEN 1M, M-Smart, M-Plan, M-Pure. Active colour display to indicate function and status. Background colour w/b and display brightness adjustable. Display of set and actual temperature. Room Temperature Extension Unit for indoor rooms, Range -10 to +50 °C. Simple setpoint adjustment via separate +/- buttons. 1 Bit +/-, 1 Byte oder 2 Byte absolute object for setpoint adjustment. Limit values min/max, min/max memory. Controlling of the room temperatur in interaction with MDT AKH- Heating Actuators. Ventilation control by hand or automatic operation. Installation in a installation box with included support ring. Recommended installation height: 1,60 m. Integrated bus coupling unit. 3 year warranty.
Room Temperature Extension Unit Smart 63, studio white glossy finish. With colour display, temperature and humidity sensor. Flush mounted. Integrated BCU. Fits 63 mm systems/ranges: e.g. Busch-Jaeger future linear, solo, carat und Busch-axcent. Active colour display to indicate function and status. Background colour w/b and display brightness adjustable. Display of set and actual temperature. Room Temperature Extension Unit for indoor rooms, Range -10 to +50 °C. Simple setpoint adjustment via separate +/- buttons. 1 Bit +/-, 1 Byte oder 2 Byte absolute object for setpoint adjustment. Limit values min/max, min/max memory. Controlling of the room temperatur in interaction with MDT AKH- Heating Actuators. Ventilation control by hand or automatic operation. Installation in a installation box with included support ring. Recommended installation height: 1,60 m. Integrated bus coupling unit. 3 year warranty.
Room Temperature/Humidy sensor 55, White glossy finish. Flush mounted. Integrated BCU. Fits 55 mm systems/ranges: – GIRA Standard 55, E2,E22, Event, Esprit. – BERKER S1, B3, B7. – JUNG A500, Aplus, Acreation, AS500. – MERTEN 1M, M-Smart, M-Plan, M-Pure. Room temperatur sensor for indoor rooms Range -10 to +50 °C. Humidy sensor with dew point calculation. Message when leaving the comfort zone. Limit values min/max, min/max memory. Installation in a installation box with included support ring. Recommended installation height: 1,60 m. Integrated bus coupling unit. 3 year warranty.
Room Temperature/Humidy sensor 63, studio white glossy finish. Flush mounted. Integrated BCU. Fits 63 mm systems/ranges: e.g. Busch-Jaeger future linear, solo, carat und Busch-axcent. Room temperatur sensor for indoor rooms Range -10 to +50 °C. Humidy sensor with dew point calculation. Message when leaving the comfort zone. Limit values min/max, min/max memory. Installation in a installation box with included support ring. Recommended installation height: 1,60 m. Integrated bus coupling unit. 3 year warranty.
Safety Module, 2SU MDRC. MDRC device. Increases the safety of the protected line in the inner and in the outdoor area and protects against manipulations. Easy retrofitting in existing KNX installations. Blocks the connection and prevents the programming and unloading of KNX devices within the line. Safety function is started automatically after bus voltage recovery and/or programming of the Safety Module. Safety function can be temporally disabled by pressing the button on the device or 14 Byte telegram. Safety function for detecting a failed device in the line. Active or passive monitoring of up to 100 KNX devices. Alarm is stored as plain text message in the internal ring memory. Quick application download (long frame support for ETS5). 3 year warranty.
Temperature Controller 8-fold, 2SU, MDRC. MDRC device.Temperature range -20 to +110 °C. Selectable temperature controller (PI, Two-position, PWM). Temperature measurement by separate KNX temperature sensors. Limit values min/max. Frost-/heat protection alarm. Min/max memory. Cyclical sending adjustable. Day-/night-/frost-/heat protection operation, cooling function. Status feedback by HVAC and RHCC status objects. Operation mode can be set via Bit/Byte objects. Desired value can be given by visualisation, e.g. MDT VisuControl. 3 year warranty.
Temperature Controller/Sensor 2-fold, flush mounted. Temperature measurement by separate PT 1000 sensors. To measure the inside/outside temperature (e.g. with SCN-PTST1.01 or SCN-PTST3.01). Temperature range -20 to +110 °C. 2-fold temperature sensor for HVAC, integrated controller. Selectable temperature controller (PI, Two-position, PWM). Temperature measurement by separate PT 1000 sensors. Limit values min/max, frost-/heat protection alarm, min/max memory. Cyclical sending of contact status adjustable. Day-/night-/frost-/heat protection operation, cooling function. Status feedback by HVAC and RHCC status objects. Operation mode can be set via Bit/Byte objects. Setpoint value via visualisation, e.g. MDT VisuControl. Integrated bus coupling unit. 3 year warranty.
Temperature Controller/Sensor 4-fold, flush mounted. Temperature measurement by separate PT 1000 sensors. To measure the inside/outside temperature (e.g. with SCN-PTST1.01 or SCN-PTST3.01). Temperature range -20 to +110 °C. 4-fold temperature sensor for HVAC, integrated controller. Selectable temperature controller (PI, Two-position, PWM). Temperature measurement by separate PT 1000 sensors. Limit values min/max, frost-/heat protection alarm, min/max memory. Cyclical sending of contact status adjustable. Day-/night-/frost-/heat protection operation, cooling function. Status feedback by HVAC and RHCC status objects. Operation mode can be set via Bit/Byte objects. Setpoint value via visualisation, e.g. MDT VisuControl. Integrated bus coupling unit. 3 year warranty.
Temperature Controller/Sensor 6-fold, surface mounted. Surface mounted device for PT 1000 sensors up to 12m cable length. Temperature range -20 to +110 °C. 6-fold temperature sensor for HVAC, integrated controller. Selectable temperature controller (PI, Two-position, PWM). Temperature measurement by separate PT 1000 sensors. Limit values min/max, frost-/heat protection alarm, min/max memory. Cyclical sending of contact state adjustable. Day-/night-/frost-/heat protection operation, cooling function. Status feedback by HVAC and RHCC status objects. Operation mode can be set via Bit/Byte objects. Setpoint value via visualisation, e.g. MDT VisuControl. Surface mounted wiring box. Integrated bus coupling unit. 3 year warranty.
Weather Station Home. Outdoor installation on wall or pole. 3 channels for sun protection to control blind/shutter. Sun protection up to 3 facades. Offers wide functions to control facades (2 switching thresholds, teach in function). Central shutter control for Up/Down via brightness value (with time delay). Brightness value for east, south, west, twilight. Generates a day/night object. Wind speed value, alarm if wind speed exceeds limit. Temperature value. Suited to control facades at home. Installation on wall or pole. 5 m connection cable. No additional power supply required. Integrated bus coupling unit. 3 year warranty.
In order to provide you a personalized shopping experience, our site uses cookies. By continuing to use this site, you are agreeing to our cookie policy.