Extensions

Showing 33–48 of 60 results

  • Lutron HomeWorks HQP7-2 – QSX 2-Link Processor

    0 out of 5
  • Lutron HWQS Hybrid Wired/Wireless RF System Repeater – 868 limited MHz

    0 out of 5
  • Lutron QS Contact closure input/output interface

    0 out of 5
  • Lutron QS DMX interface

    0 out of 5
  • Lutron QS Sensor Module

    0 out of 5
  • Lutron RA2 Aux Repeater

    0 out of 5
    د.إ1,009

    RA2 Select Wireless Repeater Hub Extender: Colour: Black Expands RF range from hub by up to 9m Up to 4 wireless repeaters can be added to the main repeater hub to extend the range. Easily adds to an existing system through the Lutron App The Lutron App is compatible with iOS devices version 8.0 or…

  • Lutron RA2 Select Main Repeater

    0 out of 5
    د.إ1,199

    RA2 Select Main Repeater Hub: Colour: Black Connects to the Wi-Fi router via an Ethernet connection Compatible with Amazon Alexa, Google Assistant, Sonos, Apple Homekit, Honeywell Wi-Fi-Fi Thermostats, IFTTT, Logitech Harmony and Samsung SmartThings Compatibility: RA2 Select dimmers, RA2 Select switch/fan controls, Sivoia QS Triathlon and Sivoia QS Wireless roller shades, draper track, Kirbé© and…

  • MDT Analog I/O 2-fold, flush mounted, 0-10V, In-/Output shiftable

    0 out of 5
    د.إ589.60

    Analog I/O 2-fold, flush mounted, 0-10 V, In-/Output shiftable. Suitable as analog output to control ventilation systems and other systems with 0-10 V input. Also useful as an analog input to engage rotation speed or other 0-10 V values. Each channel can be configured independently (In-/output). In/outputs are galvanically isolated from the bus. In/outputs are galvanically connected together. Voltage for output operation is generated inside the actuator. No external power supply required. Input operation 0-10 V / 2-10 V or 0-20 mA / 4-20 mA (switchable). – Adjustable conversation of measuring unit and DPT. – Min/max function, wire breakage detection. – Threshold and traffic light function. Output functions 0-10 V: – Control by 1 Byte, 2 Byte or 1 Bit objects. – Day/night function to limit control value. – Emergency mode if given value fails. Flush mounted in socket. Dimensions (W x H x D): 41 mm x 41 mm x 12 mm. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Analog I/O 4-fold, 2SU MDRC, 0-10V, In-/Output shiftable

    0 out of 5
    د.إ784.91

    Analog I/O 4-fold, 2SU MDRC, 0-10 V, In-/Output shiftable. Suitable as analog output to control ventilation systems and other systems with 0-10 V input. Also useful as an analog input to engage rotation speed or other 0-10 V values. Each channel can be configured independently (In-/output). In/outputs are galvanically isolated from the bus. In/outputs are galvanically connected together. Voltage for output operation is generated inside the actuator. No external power supply required. Input operation 0-10 V / 2-10 V or 0-20 mA / 4-20 mA (switchable). – Adjustable conversation of measuring unit and DPT. – Min/max function, wire breakage detection. – Threshold and traffic light function. Output functions 0-10 V: – Control by 1 Byte, 2 Byte or 1 Bit objects. – Day/night function to limit control value. – Emergency mode if given value fails. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Binary Input 16-fold, 8SU MDRC, Contact Inputs

    0 out of 5
    د.إ1,709.84

    Binary Input 16-fold, 8SU MDRC, Contact Inputs. Binary Input to connect potential free contacts. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs. (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. Internally generated query voltage of 12 V. 3 year warranty.

  • MDT Binary Input 16-fold, 8SU MDRC, Inputs 230 V AC

    0 out of 5
    د.إ1,709.84

    Binary Input 16-fold, 8SU MDRC, Inputs 230 V AC. Binary Input detection of 230 V AC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs. (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. 3 year warranty.

  • MDT Binary Input 16-fold, 8SU MDRC, Inputs 24 V AC/DC

    0 out of 5
    د.إ1,709.84

    Binary Input 16-fold, 8SU MDRC, Inputs 24 V AC/DC. Binary Input detection of 12-24 V AC/DC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs. (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. 3 year warranty.

  • MDT Binary Input 32-fold, 12SU MDRC, Contact Inputs

    0 out of 5
    د.إ2,472.64

    Binary Input 32-fold, 12SU MDRC, Contact Inputs. Binary Input to connect potential free contacts. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs. (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. 3 year warranty.

  • MDT Binary Input 4-fold, 2SU MDRC, Contact Inputs

    0 out of 5
    د.إ825.44

    Binary Input 4-fold, 2SU MDRC, Contact Inputs. Binary Input to connect potential free contacts. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. Internally generated query voltage of 12 V. 3 year warranty.

  • MDT Binary Input 4-fold, 2SU MDRC, Inputs 230 V AC

    0 out of 5
    د.إ825.44

    Binary Input 4-fold, 2SU MDRC, Inputs 230 V AC. Binary Input detection of 230 V AC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. Internally generated query voltage of 12 V. 3 year warranty.

  • MDT Binary Input 4-fold, 2SU MDRC, Inputs 24 V AC/DC

    0 out of 5
    د.إ825.44

    Binary Input 4-fold, 2SU MDRC, Inputs 24 V AC/DC. Binary Input detection of 12-24 V AC/DC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. Internally generated query voltage of 12 V. 3 year warranty.

End of content

End of content