Servers

Showing all 5 results

  • MDT IP Interface with IP Secure and Data Secure, 2SU MDRC, with email and time server functions

    0 out of 5
    د.إ954.42

    IP Interface with IP Secure and Data Secure, 2SU MDRC, with email and time server functions. To enable bidirectional communication between PC and the KNX bus via TCP/IP. 4 simultaneous connections possible. Programming the KNX bus via TCP/IP. Power supply by KNX bus, no external bus power supply required. Encrypted transmission at sending emails. Time server functions to send time and date on the KNX bus. Supports extended group addresses. KNX IP Secure and KNX Data Secure (from ETS 5.7). Secure access to the KNX bus through IP Secure with security key. Firmware can be updated. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT IP Router with IP Secure and Data Secure, 2SU MDRC, with email and time server functions

    0 out of 5
    د.إ1,536.65

    IP Router with IP Secure and Data Secure, 2SU MDRC, with email and time server functions. Functions as KNX IP Interface, but with KNX line coupler functionality. To enable bidirectional communication between PC and the KNX bus via TCP/IP. 4 simultaneous connections possible. Programming the KNX bus via TCP/IP. Power supply by KNX bus, no external bus power supply required. Encrypted transmission at sending emails. Time server functions to send time and date on the KNX bus. Supports extended group addresses. KNX IP Secure and KNX Data Secure (from ETS 5.7). Secure access to the KNX bus through IP Secure with security key. Firmware can be updated. Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT KNX Modbus Gateway RTU485, 2TE, REG

    0 out of 5
    د.إ1,415.04

    KNX Modbus Gateway RTU485, 2TE, REG. Designed for bidirectional Data exchange between Modbus RTU- and KNX-products. Master- / Slave-Mode for all channels separately selectable. Comprehensive binary- and arithmetical mathematical functions configurable for each channel. Easy scaling settings. Value range conversion adjustable for each channel. Multi Read / Write Functionality on the Modbus-side. Slave ID for each channel separately configurable. 20 Value comparison blocks each with 4 comparable values and operations. Universal applicable, supports multiple Modbus- and KNX-Data types. No additional Modbus Power supply required. Power is provided over the KNX connection. Modbus / KNX galvanically separated. Developed and produced in Engelskirchen. 3 Year warranty.

  • MDT Line Coupler with Data Secure, 2SU MDRC

    0 out of 5
    د.إ1,109.19

    Line Coupler with Data Secure, 2SU MDRC. MDRC device. Line Coupler to connect two KNX lines to each other. Electrical isolation between the lines. Separate bus power supply for each line required. Filter functions to reduce bus load. Supports extended group addresses. Supports KNX Data Secure (from ETS 5.7). Quick application download (long frame support for ETS5). 3 year warranty.

  • MDT Logic Modul, 2SU MDRC

    0 out of 5
    د.إ733.32

    Logic Modul, 2SU MDRC. MDRC device, with 4 free to use LED indicators. 24 independent function blocks assignable: Universal logic with up to 5 conditions. Logic gates with (AND,OR/XOR), each with 8 inputs. Cyclical sending or quering of values. Value storage if the bus voltage fails. Monitoring of telegrams, Filter functions. Converting of data point types, Time functions. Multiplexer/Partition control. Min-/Max/Average value, Universal calculator. Converting to PWM, Telegram multiplier/sequencer. Quick application download (long frame support for ETS5). 3 year warranty.

End of content

End of content